Acton, MA

Acton-Boxborough Regional High School Pool

Scope/Solutions

The natatorium was constructed in the early 1970s as an addition to the high school. The pool and deck are constructed of reinforced concrete and precast plank forms the ceiling. SGH evaluated the condition of the natatorium as part of a school improvement plan and subsequently designed repairs.

The building committee wanted to ensure that the natatorium would meet the requirements for the design life of the new school addition. SGH performed a review of the pool operations, a delamination and corrosion survey of the pool deck, and corrosion testing and chloride sampling of the precast concrete roof structure and cast-in-place concrete deck and pool walls.

 

Based on the results of the investigation, SGH developed repair options to address deterioration, chloride contamination, and leakage. We developed concrete repairs, including completely replacing the deck, locally repairing other concrete elements, and integrating a modern pool water circulation and collection system in the pool edge.

 

SGH provided construction administration services, including reviewing contractor submittals, observing repair work to compare with the design intent, and troubleshooting unforeseen field conditions.

Project Summary

Icon: completion-date

2005

Completion Date
Solutions
Repair & Rehabilitation
Services
Structures | Applied Science & Research
Markets
Education
Client(s)
Design Partnership of Cambridge
Specialized Capabilities
Repair & Strengthening | Materials Science | Microscopy

Key team members

Paul Kelley
Consulting Principal

Additional Projects

Northeast

Bentley University, Campus-wide Condition Assessments

To better plan for capital expenses, the university needed to understand the condition of their buildings. SGH performed building enclosure condition assessments, recommended facade and roofing repairs, and estimated costs for the university’s consideration.
Explore
Northeast

Bates College, Campus Avenue Project

Bates College wanted to expand their student housing while increasing their visibility along Campus Avenue. The two L-shaped buildings, which share a common plaza area, will accommodate more than 200 students. SGH consulted on the building enclosure design.
Explore