Lenexa, KS
Hyatt Place
Scope/Solutions
The six-story hotel also houses a one-story conference center at the south end. Shortly after construction, hotel personnel observed leaks at several locations. The original contractor asked SGH to investigate the leaks, develop a repair plan, and oversee repairs.
SGH investigated the reported leakage and collaborated with the contractor to develop a repair plan that could be implemented while the building remained occupied. Highlights of our repair design include the following:
- Installing flashing and interior louver waterproofing without removing the existing windows or louvers
- Installing pan flashing below the curtain wall by lowering the front edge of the sill to create the necessary slope for drainage
- Developing details to integrate the weather barrier between adjacent walls systems
- Adding through-wall flashing at the roof line and where a low roof meets a rising wall
We performed confirmation testing to verify repairs successfully addressed the issues.
Project Summary
Solutions
Repair & Rehabilitation
Services
Building Enclosures
Markets
Commercial
Client(s)
The Weitz Company, LLC
Specialized Capabilities
Condition Assessments | Roofing & Waterproofing
Key team members


Additional Projects
Midwest
Willis Tower
Designed by Gensler, Catalog is a five-story dining, retail, and entertainment hub located at the base of the 1970s Willis Tower. SGH provided structural engineering services for the design of the entrances.
Midwest
Hess Corporation Tioga Office Complex
Constructed in 2009, the Tioga Office Complex is the administrative hub for Hess Corporation’s Bakken Oil Field operations. After occupying the complex, Hess personnel observed water leakage in the office building. SGH investigated the cause of leakage and recommended options for repairs.